Most popular

What is pin 86 on a relay?

What is pin 86 on a relay?

85 and 86 are the coil pins while 30, 87, and 87a are the contact pins. Realizing that 85 and 86 are the coil pins, these pins will be transferring the current through the coil. 85 will be used to ground your relay, while 86 will be connected to the switchable power.

What is NO and NC in relay?

A: NO, NC refer to the relay being de-energized or powered off. So, to have “open to alarm” condition, the NO contact would be used for this. NC means normally-closed contact. NO means normally-open contact. When the relay coil is de-energized, NC contact becomes open, and NO contact closes.

What is the common pin on a relay?

The COM (Common) connection of a relay is the part of the relay that moves. When a relay is off, the COMMON is connected to the NC (Normally Closed). The NO (Normally Open) connection of the relay is not connected until the relay turns on. When the relay turns on, the COMMON move from NC to NO.

Why is the handle on the 86 relay not closed?

The latching nature of the 86 relay means none of these circuit breakers may be closed until someone turns the handle of the 86 relay back to the “reset” position.

Where are the resistance pins on a relay?

Turn back the relay to see pins located at its bottom part. Try to touch the probes of multimeter on a pair of pins of relay until the touched pair shows a resistance value (but not zero). **Only the relay coil pin pairs will show non-zero resistance value. **Other pin pairs will show either zero resistance or infinite resistance.

How does terminal 86 connect to terminal 85?

Terminal 87 connects the other internal switch contact to the device controlled by the relay. When you power terminal 86 and ground terminal 85, it energizes the electromagnet, which pulls the internal switch contacts closed, which connects 30 (power) to 87 (the device), which sends power to the device.

How many terminal pins are in a SPST relay?

Such relay can categorized into normally open or normally closed type. ii) Single Pole Double Throw (SPST) – Such relay has 5 terminal pins which consists of a pair of coil pins, a common pin, a normally open (NO) pin and a normally closed (NC) pin.

The latching nature of the 86 relay means none of these circuit breakers may be closed until someone turns the handle of the 86 relay back to the “reset” position.

Terminal 87 connects the other internal switch contact to the device controlled by the relay. When you power terminal 86 and ground terminal 85, it energizes the electromagnet, which pulls the internal switch contacts closed, which connects 30 (power) to 87 (the device), which sends power to the device.

What is the code for an auxiliary relay?

An important type of “accessory” relay, especially for legacy electromechanical protective relays, is the so-called auxiliary or lockout relay, designated by the ANSI/IEEE number code 86.

Turn back the relay to see pins located at its bottom part. Try to touch the probes of multimeter on a pair of pins of relay until the touched pair shows a resistance value (but not zero). **Only the relay coil pin pairs will show non-zero resistance value. **Other pin pairs will show either zero resistance or infinite resistance.

Author Image
Ruth Doyle